Ausstattungsliste: Ashly Audio nX 3.0
Features | |
Amplifier | |
Protēa™ DSP audio processing on inputs and outputs including | |
Automatic Feedback Suppressor | |
Auto-Mixer | |
Ambient Noise Compensation | |
Dynamics processing with auto-ducker | |
EQ & crossovers including FIR filters | |
Time alignment and tower delay | |
Scheduled noise-masking with Real-Time Clock | |
Swept AC load-analysis with baseline logging | |
FIR Filter capable, dynamics, gain, equalization, 2×4 or 4×4 matrix mixer, crossover, delay, metering, and signal generator functions for test and noise masking applications | |
Precision swept load impedance monitoring of each amplifier channel | |
Ethernet Control and monitoring of amplifier functions, with front panel COM activity LED | |
Serial data port for use with Ashly remote control devices, or optional RS- 232 converter for third party controllers (INA-1) | |
Use Protea™ Software to remotely disable all front panel controls, including the on/off switch, for a tamper-proof installation | |
Real-Time Clock with Event Scheduler | |
Instant Standby Mode 30% reduction in power consumption with on/off and Preset Recall, both via contact closure, software control, or event scheduler | |
Programmable power-on delay | |
Aux preamp outputs, and fault condition logic outputs | |
Optional Cobranet™ or Dante® and AES3 digital audio input with passthru | |
Rear panel DIP switches select low impedance (2, 4, and 8 Ohm), constant voltage (70V or 100V), high pass filter, limiter and input gain on each channel | |
Ashly Energy Management System (EMS) for increased efficiency) automatic <1Wsleep-mode (defeatable) | |
Switch mode power supply automatically detects 120V or 240V AC operation | |
Extensive protection circuitry | |
Continuously variable cooling fans | |
Front panel power switch and level controls (can be disabled for security) | |
Multiple internal power supplies provide increased channel separation and reliability | |
Remote DC level control on each input channel (2 RU models only) | |
Genuine Neutrik® connectors on 2 RU models for security, safety, and reliability | |
Safety / Compliance: cTUVus, CE, FCC, RoHS | |
Specification | |
2Ω | 3,000W |
4Ω | 2,000W |
8Ω | 1,250W |
4Ω (br) | 6,000W |
8Ω (br) | 4,000W |
25V | - |
70V | 2,450W |